UK testing facilities
Axis Test Laboratories Ltd
Unit 11A, Oakway Court, Meadowfield Industrial Estate, Meadowfield, Durham, DH7 8XD, England, United Kingdom
Access: Yes
Testing capabilities
- Vibration
- Shock and impact
- Climatic and environmental exposure
Services
Sinusoidal, random, sine-on-random and random-on-random vibration; climatic cold, dry heat and humidity cycling; corrosion/salt-spray; drop and shock testing. Operator also describes aerospace/aviation test support; accredited scope must be checked for each method.
Equipment
Vibration: 2–3,000 Hz; maximum peak-to-peak displacement 50 mm. Climatic chambers: −70°C to +180°C; humidity 10–98% RH. Specific shock limits not published in reviewed pages.
Standards
UKAS ISO/IEC 17025:2017 testing laboratory 7670 (operator-reported); operator pages list BS EN/IEC 60068, BS EN 60945, MIL-STD-810 and DEF STAN 00-35. Verify the current schedule for each requested method.
Contact
Operator-wide contact: Email: info@axistestlaboratories.co.uk; Phone: +44 1913784653; Laboratory Manager (name not stated): ian.howson@axistestlaboratories.co.uk; operator-wide fallback: info@axistestlaboratories.co.uk; Phone: +44 191 378 4653
Approximate location
DH7 8XD · Postcode area location