Back to UK testing facilities

UK testing facilities

Resonate Testing Laboratory

Resonate Testing Ltd

Unit 1, Bridge Technology Park, Carnagat Lane, Chancellors Road, Newry BT35 8XF

Access: Yes

Visit facility website

Testing capabilities

  • Vibration
  • Shock and impact
  • Thermal vacuum
  • Climatic and environmental exposure
  • Materials and structural testing
  • Inspection and failure analysis
  • Contamination, outgassing and leak testing
  • Electrical, power and batteries
  • Functional and integrated-system testing
  • Fire and flammability

Services

Mechanical and environmental testing for space, aerospace, batteries and electrical/mechanical products; vibration, SRS shock, fire/flammability, combined temperature-vibration, TVAC, battery performance/safety/abuse/lifecycle, temperature/humidity/altitude, corrosion/IP and packaging tests; bespoke fixture and rig design.

Equipment

Purpose-built 7,500 sq ft facility; combined vibration/environmental laboratory stated to support temperature-vibration up to 54 kN; multiple vibration tables, fire lab and general mechanical lab. Other limits depend on test setup and are not fully published.

Standards

UKAS-accredited ISO 17025; website also states ISTA and parent-group ISO 9001:2015. Specific schedule scope not reviewed here. | Accreditation: UKAS ISO/IEC 17025 certificate 9373; mirror status active; current status requires direct register confirmation.

Contact

Operator-wide contact: Email: info@resonatetesting.com; Phone: +44 2890736390

Approximate location

Newry ยท Town location

View approximate location on OpenStreetMap

Sources