UKAS schedule 1756 identifies Technical Materials Laboratory at Unit L Kingsfield Business Centre, Redhill, with testing only at that address. It lists chemical permeation/degradation methods for protective clothing, gloves and footwear, plus selected physical textile/fabric methods. Method-specific restrictions and excluded flammability work are retained.

Reviewed by Arc · About this review

Key facts

Public information not available. Contact test facility provider for more information.

Testing capabilities

Protective clothing chemical testing

The scope lists liquid/gas/solution chemical permeation using FTIR, ion-selective electrode or pH measurement, chemical resistance/degradation of protective gloves and prolonged chemical contact for protective footwear. Specific hydrofluoric-acid and mixture methods are separately listed.

Selected textile physical tests

Listed physical methods include flex cracking to ISO 7854 Method B only, strip tensile excluding wet testing, tear, abrasion, seam grab tensile and puncture resistance. The protective-clothing classification rows carry explicit exclusions including ignition resistance and flammability.

Equipment and published limits

Public information not available. Contact test facility provider for more information.

Access and contact

The schedule publishes Deborah House, deborah.house@techmatlab.com and +44 (0)1737 857391. Describe the protective material/product, chemical and exposure method or physical property, specimen and report requirements.

Facility contact

Address
Unit L Kingsfield Business Centre, Philanthropic Road
Redhill, Surrey, RH1 4DP

Standards and accreditation

UKAS 1756 — ISO/IEC 17025:2017
Issue 041 dated 4 April 2025 retains the named permeation and physical-test references, methods and exclusions. The schedule marks several older references withdrawn; no full protective-product compliance certificate is inferred.

What to confirm with the facility

  • Strip tensile excludes wet testing and flex cracking is Method B only. Protective-clothing classification has listed cleaning/flexing/pre-conditioning, liquid-penetration, pull-strength and ignition/flammability exclusions. Confirm the exact applicable subset.
  • Confirm chemical/specimen suitability, exposure technique, preparation, method edition, accredited report scope, availability and quotation.

Before requesting a test

Public information not available. Contact test facility provider for more information.

Frequently asked questions

Public information not available. Contact test facility provider for more information.

Further reading

Sources and review

Arc reviewed the original sources on 2026-10-13. The cited material supports the bounded site information presented here. Test suitability and commercial arrangements require direct confirmation.

Arc publishes this directory entry and does not operate the test facility. Suggest a correction to Arc with a supporting source.

  1. UKAS 1756 Technical Materials Laboratory, issue 041

    United Kingdom Accreditation Service (UKAS) · Reviewed

    Issue 041 dated 4 April 2025 is Redhill address-only. Permeation techniques, specific protective products, textile Method B/strip/grab methods and explicit wet-testing, flammability/ignition/pre-conditioning exclusions remain attached to their rows; withdrawn references are not treated as current editions.