Back to UK testing facilities

UK testing facilities

UCL Mullard Space Science Laboratory Assembly, Integration and Test Facilities

University College London, Mullard Space Science Laboratory

Holmbury St Mary, Dorking, Surrey, England

Access: Yes

Visit facility website

Testing capabilities

  • Vibration
  • Thermal vacuum
  • Contamination, outgassing and leak testing
  • Functional and integrated-system testing

Services

Space-flight hardware assembly, integration and environmental qualification/acceptance testing; thermal-vacuum, cryogenic, vacuum-bakeout, vibration and contamination-control/outgassing support.

Equipment

20 K and 77 K cryostats, thermal-vacuum and vacuum-bakeout facilities, Ling Dynamics vibration facility, ISO 5/6/8 cleanrooms, residual-gas analysers to 200/300 amu and quartz-crystal microbalances; MSSL thermal-control systems are described as typically 150°C to -250°C in engineering documentation.

Standards

MSSL states its AIT work follows ESA ECSS and NASA standards; no laboratory accreditation stated. ISO cleanroom classes are published as facility conditions, not testing accreditation.

Contact

Email: office@mssl.ucl.ac.uk; Phone: +44 (0)1483 204100; Named contacts: Prof Steve Baker (Space Instrumentation and Enterprise Lead; current role listed on UCL page), Prof Lucie Green (Knowledge Exchange and Impact Lead; current role listed on UCL page)

Approximate location

Holmbury St Mary · Town location

View approximate location on OpenStreetMap

Sources